Exceptionally dependable battery backup
We start with premium quality batteries. Thermally
isolate them for maximum life. And employ unique
charging circuitry attuned to the specific battery
characteristics of each model to speed recovery and
minimize stress on batteries. Automatic monitoring of
battery condition ensures readiness, gives plenty of
warning when replacement is recommended. And our
patented battery pack allows replacement in under a
minute without tools or training, without downtime,
and without risk.
Proven durability, backed by a 5-year warranty
ONEAC UPSs robust design is impervious to the
harshest electrical environments. Designed and manufactured
under ISO9001 quality procedures, ON Series
UPSs are exceptionally reliable. With an average mean
time between failures more than twice as long as
leading competitors. No surprise, then, that we back
our UPSs with greater confidence — 5 years on all
power and control systems, 2 years on the battery
sub-system.
Power Conditioning
ONEAC’s unique power conditioning architecture provides superior protection
against the full range of power line disturbances. Components include:
Full output isolation: ONEAC’s proprietary transformer design integrates power
conditioning magnetics and voltage conversion magnetics in a single compact
unit. Provides superior protection against lightning and other high energy surges.
Virtual Kelvin Ground®: Eliminates the full spectrum of conducted power line
noise (from 50 kHz to 10 MHz) in all modes, reduces the effect of electrostatic
discharge (ESD) and provides an exceptionally clean signal reference ground for
electronic systems.
Communications
Basic mode provides standard protocols recognized by UPS monitoring software
supplied with Windows NT, NetWare and Banyan operating systems.
Advanced mode uses ONEAC’s content-rich ASCII packets to communicate with
ONEAC’s MopUPS® family of UPS monitoring software for NetWare,Windows NT,
a full catalog of UNIX operating systems and SNMP.
Global Approvals
Models for North America are FCC Class A certified and listed under UL 1778
and CSA22.2 safety standards. Models for Europe carry the GS and CE marks
and are tested under the following standards: EN50091, EN60950, EN50081-1,
EN55022 (CISPR 22), EN50082-1.
Nominal input voltage: 120 VAC, 60 Hz & 230 VAC, 50/60 Hz
Surge voltage withstand capability: ANSI/IEEE C62.41 Category
A&B, 6 kV/200 & 500 Amp, 100 kHz ringwave
Surge voltage let-through (max): less than 10 V Normal mode (L-N),
less than 0.5 V Common mode (N-G) when subjected to 6kV ANSI/IEEE
C62.41 Cat. A
Normal & common mode clamping response time: Instantaneous
Transfer time (typical/max): < 3.0 / 3.5 milliseconds
On-battery output voltage: sine wave
ONBoost: boosts output voltage 11% above input voltage if between
-21% & -15% of nominal
Load power factor range (crest factor): UPS .65 to 1.0 (3) — will
support loads rated 0.5 to 1.0 (<5)
Batteries: sealed, maintenance-free lead acid with a 3-6 year typical
lifetime
Recharge time to 60% available capacity: 4 hours per battery cabinet
Universal
NOT RATED FOR MEDICAL USE